ST-TLU3A+
| Dimensions | 305.8 × 258 × 530 cm |
|---|---|
| Measurable parameters | I-V, P-V curve, short-circuit current Isc, open-circuit voltage Voc, maximum power Pmpp, cell efficiency Eff, fill factor FF, current at maximum power point Impp, voltage at maximum power point Umpp, series resistance Rser, parallel resistance Rshunt, solar cell surface temperature, Iuld (current at fixed point voltage), Puld (power at fixed point voltage), where Uld can be set arbitrarily |
| Measurable module sizes | 2600mm×1600mm |
| Test speed | 240 pcs/ hours |
| Flash time | The 10-150ms is adjustable |
| Lamp life | >100000 flashes / 10ms |
| Irradiance range | 500-1200W/m2 |
| Spectral Matching | 0.875-1.125 (Grade A+) |
| Irradiance Instability STI | ≤0.25% (Grade A+) |
| Irradiance Instability LTI | ≤1% (Grade A+) |
| Irradiance inhomogeneity | ≤1% (Grade A+) |
| Spectral range (IEC 60904-9:2020) | 300-1200nm |
| Repeat test accuracy(40 Flashes) | <0.1% |
| Measurement range | Voltage range is 1v/10v/50v/100v/150v/200v |
| Measurement resolution | 16bit ( Measurement resolution of 0.003%) |
| Lamp type | Direct-tube xenon lamp |
| Operating mode | Single pulse |
| Working power supply | 200-240V,10A,50/60HZ, Single-phase |
| Equipment size | Light source box:3058x2580x5300mm |
| Equipment weight | Light source box: 1.8t Electrical cabinet: 0.28t |